Programming the Module with SMS
The MobilTherm-2-IP67 module can also be programmed remotely using SMS. The table below lists the most common memory locations, their functions, and their factory default contents. Commands must be entered precisely for the module to execute the desired action.
Memory Locations and SMS Commands:
| Memory ID. | Function | Factory Default | User Content |
|---|---|---|---|
| 001 | SMS center number | +36309888000 | |
| 002 | Max. number of SMS sent in 2 hours | 20 | |
| 003 | Module arming SMS command | Elesites | |
| 004 | Module disarming SMS command | Tiltas | |
| 005 | Automatic test time | 72:00:00 | |
| 010 | Phone number 1 (master) | +36301234567 | |
| 011 | Phone number 2 | ||
| 012 | Phone number 3 | ||
| 013 | Phone number 4 | ||
| 020 | Name of thermometer 1 | Living room | |
| 022 | Thermometer 1 low alarm | 16 | |
| 026 | Thermometer 1 notifications for signals | S1,V1 | |
| 030 | Name of thermometer 2 | Kitchen | |
| 031 | Thermometer 2 high alarm | 28 | |
| 032 | Thermometer 2 low alarm | 18 | |
| 033 | Thermometer 2 notifications for signals | S1,V1 | |
| 038 | Probe error message | Probe error | |
| 039 | Probe OK error message | Probe OK | |
| 040 | Name of input 1 | Alarm | |
| 041 | Input 1 when activated | sounded | |
| 042 | Input 1 when deactivated | silenced | |
| >043 | Input 1 notifications for signals | S1,V1 | |
| 050 | Power supply error name | Power supply | |
| 051 | Power supply error occurred | error | |
| 052 | Power supply error resolved | OK | |
| 053 | Power supply error notifications | S1,V1 | |
| 060 | Name of input 2 | Water level indicator | |
| 061 | Input 2 when activated | high level | |
| 062 | Input 2 when deactivated | normal level | |
| 063 | Input 2 notifications for signals | S1,V1 | |
| 070 | Name of output 1 | Boiler | |
| 071 | Output 1 activate command | on | |
| 072 | Output 1 deactivate command | off | |
| 073 | Output 1 relay timing | 00:15:00 | |
| 080 | Name of output 2 | Boiler | |
| 081 | Output 2 activate command | turn on | |
| 082 | Output 2 deactivate command | turn off | |
| 083 | Output 2 relay timing | 01:00:00 | |
| 090 | Service notifications for signals | R1,V1,S1 | |
| 091 | Acknowledged events | H1,J1,A1,B1,T | |
| 098 | Thermometer offset | +0.0,+0.0 | Not editable! |
| 500 | Module type | MobilTherm-2-xC | Not editable! |
| 501 | Software version | 1.14 | Not editable! |
| 502 | Signal strength status message | 0 | Not editable! |
| 503 | Provider name | ? | Not editable! |
| 504 | Thermometer-1 | 0 | Not editable! |
| 505 | Thermometer-2 | 0 | Not editable! |
| 506 | Input-1 | 0 | Not editable! |
| 507 | Input-2 | 0 | Not editable! |
| 508 | Output-1 | 0 | Not editable! |
| 509 | Output-2 | 0 | Not editable! |
| 510 | Power supply status value | 0 | Not editable! |